TM 9-2320-302-20
0026 00-2
OIL SAMPLE VALVES REPLACEMENT - CONTINUED
0026 00
INSTALLATION
1.
Install bracket (6) on mounting bracket (11) with washer (10), screw (9), washer (8), and new lock nut (7).
WARNING
Adhesives and sealing compounds can burn easily, can give off harmful vapors, and are harmful to skin and
clothing. To avoid injury or death, keep away from open fire and use in a well-ventilated area. If adhesive or
sealing compound contacts skin or clothing, wash immediately with soap and water.
2.
Lightly coat threads of sample valve (5) and elbow (4) with pipe sealing compound. Install sample valve and elbow on
bracket (6).
3.
Connect hose (1) to elbow (4).
4.
Lightly coat threads of bushing (3) and connector (2) with pipe sealing compound. Install bushing and connector on oil
cooler.
5.
Connect hose (1) to connector (2).
END OF WORK PACKAGE
3
2
1
4
6
5
7
8
11
9
10