TM 9-2320-302-20
0026 00-1
OIL SAMPLE VALVES REPLACEMENT
0026 00
THIS WORK PACKAGE COVERS
Removal, Installation
INITIAL SETUP
Tools and Special Tools
Tool kit, general mechanics (Item 36, WP 0236 00)
Materials/Parts
Nut, self-locking (P/N MS51922-33)
Compound, sealing, pipe (Item 10, WP 0235 00)
References
TM 9-2320-302-10
NOTE
Engine and transmission oil sample valves are replaced the same way. Engine oil sample valve is illustrated.
REMOVAL
1.
Disconnect hose (1) from connector (2).
2.
Remove connector (2) and bushing (3) from oil cooler.
3.
Remove hose (1) from elbow (4).
4.
Remove elbow (4) and sample valve (5) from bracket (6).
5.
Remove lock nut (7), washer (8), screw (9), washer (10), and bracket (6) from mounting bracket (11). Discard lock nut.
3
2
1
4
6
5
7
8
11
9