  164    165    166    167    168  169  170    171    172    173    174  
img
. .
TM 5-2330-325-13&P
0043
FEMALE CONNECTOR REPAIR
1.
Position shell (Figure 5, Item 5) from insulator (Figure 5, Item 4) and terminal (Figure 5, Item 1) on wire lead
(Figure 5, Item 2).
2.
Remove terminal (Figure 5, Item 1) from wire lead (Figure 5, Item 2). Discard terminal (Figure 5, Item 1).
CAUTION
Remove only enough insulation to fill cavity on new terminal. Failure to comply may result
in damage to, or destruction of, equipment or mission.
3.
Remove insulation (Figure 5, Item 3) from wire lead (Figure 5, Item 2).
4.
Using crimp tool, install new terminal (Figure 5, Item 1) on wire lead (Figure 5, Item 2).
5.
Position insulator (Figure 5, Item 4) and shell (Figure 5, Item 5) over terminal (Figure 5, Item 1) on wire lead
(Figure 5, Item 2).
6.
Connect intervehicular connector and check for proper operation (WP 0005).
1
2
3
4
5
466_0128
Figure 5.
Female Connector Repair.
END OF TASK