TB 9-2320-360-13&P-2
DOOR BALLISTIC GLASS AND FRAME ASSEMBLY REPLACEMENT - CONTINUED
0014 00
INSTALLATION - CONTINUED
WARNING
For proper threat protection, ballistic glass must be correctly installed into frame. During installation,
ensure that stencil marking "THIS SURFACE TOWARDS THREAT" is located on outside of cab.
Improperly installed ballistic glass will not protect occupants. Failure to follow this warning may cause
injury or death to personnel.
Use extreme caution when handling heavy parts. Provide adequate support and use assistance during
procedure. Failure to follow this warning may result in injury to personnel.
NOTE
Door ballistic glass weighs 75 lb (34 kg).
12.
With assistance, install door ballistic glass (5) by sliding in end of channel (11).
13.
When door ballistic glass (5) in center position, lift handle (9) and rotate to original position.
14.
Lift handle (9) out of center lock hole and close door ballistic glass (5).
15.
Install spacer (2), bolt (1), washer (4), and nut (3) in bottom channel (11).
16.
Install two washers (8), bolt (7), and new locknut (6).
17.
18.
Operate door ballistic glass (5) to verify correct operation.
5
1,2,3,4
6,7,8
9
11
417-127
END OF WORK PACKAGE