TM 9-2320-363-34-2
97. USING AT LEAST THREE SHIMS WITH THICKEST IN MIDDLE, ASSEMBLE NEW SHIM PACK (58).
98. REMOVE SEVEN CAPSCREWS (57).
99. USING SUITABLE LIFTING DEVICE, LIFT INPUT SHAFT (28) 1/4-1/2 IN. (6-12 mm).
100. INSTALL SHIM PACK (58) UNDER BEARING CAGE (30). MAKE SURE SHIM PACK (58)
INSTALLATION PATTERN MATCHES BEARING CAGE (30) INSTALLATION PATTERN.
101. INSTALL FILTER SHIELD (59), SEVEN WASHERS (60), AND SEVEN CAPSCREWS (57).
17-43