TM 9-2320-363-34-2
TRANSFER CASE REPAIR (CONT)
31.
32.
33.
34.
35.
36.
37.
38.
INSTALL SHIMS (41), END CAP (42), SIX NEW LOCK WASHERS (43), AND SIX CAPSCREWS (44).
TIGHTEN CAPSCREWS TO 60 LB-FT (81 N.m).
INSTALL FABRICATED TOOL (45) IN END CAP (42).
POSITION TRANSFER CASE (46) ON SIDE.
MOUNT DIAL INDICATOR (30) ON MACHINED SURFACE ON FRONT OF TRANSFER CASE (46)
WITH DIAL INDICATOR SHAFT (47) RESTING ON CENTER SHAFT (48).
TIGHTEN FABRICATED TOOL (45) TO CHECK END PLAY. ADD OR REMOVE SHIMS (41) TO
ACHIEVE 0.003-0.006 IN. (0.08-0.15 mm) END PLAY.
REMOVE FABRICATED TOOL (45), SIX CAPSCREWS (44), SIX NEW LOCK WASHERS (43), AND
END CAP (42).
APPLY LIGHT BEAD OF ADHESIVE TO INSIDE OF END CAP (42) FLANGE AND INSTALL END
CAP (42) AS IN STEP 31.
APPLY SEALING COMPOUND TO PLUG (49) AND INSTALL PLUG.
15-18