12.
INSTALL ROUND DOWEL (11)
ROUND DOWEL (11) SHOULD
PROPERLY SEATED IN BORE.
TM 9-2320-363-34-1
IN BORE OF PUMP BODY MOUNTING SURFACE (12). TOP OF
BE 0.197 IN. (5.0 mm) FROM MOUNTING SURFACE (12) WHEN
13.
NOTE
Diamond dowel must be oriented in relation to round dowel before installing in
pump body mounting surface.
LOOSELY PLACE DIAMOND DOWEL (13) IN BORE OF PUMP BODY MOUNTING SURFACE (12)
SO ANGULAR ORIENTATION IS PERPENDICULAR TO CENTER LINE THROUGH ROUND DOWEL
(11) WITHIN 5 DEGREES.
14.INSTALL DIAMOND DOWEL (13) IN BORE OF PUMP BODY MOUNTING SURFACE (12). TOP OF
DIAMOND DOWEL (13) SHOULD BE 0.307-0,323 IN. (7.8-8.2 mm) ABOVE SURFACE (12) WHEN
PROPERLY SEATED IN BORE.
3-209