TM 9-2320-363-34-1
C A U T I O N
Injector harness terminals should be bent upward before installation to avoid
contacting surrounding surfaces and causing short circuits. However, do not
bend harness terminals after installation to prevent damage to equipment.
The following steps must be performed to provide clearance for engine
retarder wiring harness.
10. BEND INJECTOR HARNESS TERMINAL (10) UPWARD, APPROXIMATELY 90 DEGREES.
11. INSTALL INJECTOR HARNESS TERMINAL (10) ON TWO SCREWS (11). TIGHTEN SCREWS TO
12-17 LB-IN. (1.36-1.92 N.m).
12. CONNECT FUEL SUPPLY HOSE (12) TO FUEL CHECK VALVE FlTTlNG (13).
13. CONNECT FUEL RETURN LINE (14) TO VEHICLE FUEL RETURN LINE CONNECTION (15).
14. REPEAT STEPS 11 THRU 13 FOR REMAINING INJECTORS.
NOTE
Follow-on Maintenance:
Install rocker arm assemblies (page 3-183).
Prime fuel system (TM 9-2320-363-20).
3-113