TM
9-2320-363-20-1
Table 3-1.
Troubleshooting
(Cont)
Malfunction
Test or Inspection
Corrective Action
ELECTRICAL SYSTEM (CONT)
Utility Light Circuits (Cont)
2.
ONLY
ONE
UTILITY
LIGHT
OPERATING.
Step
1.
Check
backup lamp.
.
If defective,
replace
lamp (page
4-284).
Step
2.
Disconnect
lead 73B from defective
utility tight. Check for +12 VDC
at
lead 73B.
.
If +12
VDC
is present,
go to step 3. If no voltage
is
present,
repair lead 73B
(page 3-2).
Step 3.
Check for continuity
between
socket and ground.
.
If continuity
is indicated,
replace
utility light (page 4-224).
If no
continuity
is indicated,
repair ground lead (page 3-2).
3.
UTILITY
LIGHT
INDICATOR
LIGHT
NOT
OPERATING,
UTILITY
LIGHTS
OPERATING
NORMALLY.
Disconnect
lead 73A from pin D16 of warning
light bar. Check for +12 VDC
at
lead 73A.
.
If +12
VDC
is present,
troubleshoot
warning
light
circuit
(page
3-60).
If
no
voltage
is
present,
repair
lead
73A
(page
3-2).
Electric Horn Circuits
3-52