TM
9-2320-363-20-1
Table 3-1.
Troubleshooting
(Cont)
Malfunction
Test or Inspection
Corrective Action
ELECTRICAL
SYSTEM (CONT)
Auxiliary
Light Circuits
(Cont)
Step
7.
Check for +12
VDC
at auxiliary
light
power
bus.
.
If +12
VDC
is not
present,
check for continuity in lead 420JD.
If continuity
is indicated,
replace
auxiliary
lights power relay
(pages
4-197,
4-198).
2.
NO
POWER
TO
AUXILIARY
HEATER
FAN POWER
RELAY.
Disconnect
auxiliary lights accessory
lockout relay and heater
fan power relay. Check
for continuity
in lead 71AA.
.
If no continuity
is indicated,
repair
lead 71AA
(page 3-2).
Worklight
Power Receptacle
Circuits
1.
NEITHER
WORKLIGHT
POWER
RECEPTACLE
OPERATES.
Step
1.
Check worklight receptacles
15A fuse.
.
If defective,
replace
15A fuse (page
4-204).
Step
2.
Check for +12 VDC
at lead 420JD
from auxiliary
light power bus.
l
If +12
VDC
is present,
go to step 3. If no voltage is present,
repair
lead 420JD
(page 3-2).
Step
3.
Check for +12
VDC
at lead 73F for left and right worklight power receptacles.
.
If +12
VDC
is present,
repair
ground
lead
from
worklight
power
receptacles
(page
3-2).
If no
voltage
is
present,
repair
lead
73F
(page
3-2).
3-46