Table 3-1.
Troubleshooting
(Cont)
Malfunction
Test or Inspection
Corrective Action
ELECTRICAL SYSTEM (CONT)
Worklight Power Receptacle Circuits (Cont)
2.
ONE WORKLIGHT
POWER
RECEPTACLE
NOT OPERATING, THE OTHER RECEPTACLE
OPERATING
NORMALLY.
Step 1.
Check
for +12
VDC
at lead 73F to worklight power receptacle.
.
If +12 VDC
is present,
go to step
2. If no voltage
is present,
repair lead 73F
(page 3-2).
Step 2.
Check
for continuity between
receptacle
and ground.
.
If continuity is indicated,
replace defective
receptacle
(page 4-224).
If no continuity
is
indicated,
repair
ground
lead (page 3-2).
Backup Light Circuits
1.
NEITHER
BACKUP
LIGHT
OPERATES.
Step 1.
Check
backup
light 15A fuse.
.
If defective,
replace
15A fuse (page 4-204).
Step 2.
Inspect
light bulbs.
.
Replace
if broken or defective
(page
4-284).
3-49