TM 9-2320-363-20-1
Table 3-1. Troubleshooting (Cont)
Malfunction
Test or inspection
Corrective action
ELECTRICAL SYSTEM (CONT)
Power Take-Off (PTO) Circuits (All Except M915A2) (Cont)
Step 5.
Disconnect lead 200E from main cab harness. Check for +12 VDC at
lead 200E.
If +12 VDC is present, go to step 6. If no voltage is present,
repair lead 200E between PTO switch and main cab harness
(page 3-2).
Step 6.
Disconnect lead 200E from engine harness. Check for +12 VDC at lead 200E.
If +12 VDC is present, go to step 7. If no voltage is present,
repair lead 200E in main cab harness (page 3-2).
Step 7.
Disconnect lead 200E from PTO solenoid valve. Check for +12 VDC at
lead 200E.
If +12 VDC is present, go to step 8. If no voltage is present,
repair lead 200E in engine harness (page 3-2).
3-56 Change 3