TM
9-2320-363-20-1
Table 3-1.
Troubleshooting
(Cont)
Malfunction
Test or Inspection
Corrective Action
ELECTRICAL SYSTEM
(CONT)
Backup Light Circuits
(Cont)
Step
3.
Disconnect
lead 420JD
from backup
light 15A fuse.
Check
for +12
VDC
at
lead
420JD.
.
If +12
VDC
is present,
go to step 4. If no voltage is present,
repair lead 420JD
(page
3-2).
Step 4.
Disconnect
lead 120 from backup light switch.
Check
for +12 VDC
at
lead
120.
.
If +12
VDC is present,
go to step 5. If no voltage
is present,
repair lead 120 (page
3-2).
Step
5.
Disconnect
lead
120B from backup
light switch.
Press backup
light switch.
Check
for continuity
between
switch contacts.
.
If continuity is indicated,
go to step 6. If no continuity is
indicated,
replace
backup
light switch (page
4-313).
Step
6.
Disconnect
lead
120B from
chassis
harness.
Check
for +12
VDC
at
lead
120B.
.
If +12
VDC
is present,
go to step 7. If no voltage
is present,
repair lead 120B between
chassis
and backup
light switch
(page 3-2).
Step
7.
Check
for +12
VDC
at
backup
receptacle
socket
120B
connector.
.
If +12 VDC
is present,
repair
receptacle
socket ground leads to
ground (page 3-2).
If no voltage
is present,
repair lead
120B to
chassis
wiring harness
(page
3-2).
2.
RIGHT
OR
LEFT
BACKUP
LIGHT
NOT
OPERATING.
Step
1.
Check
backup
light lamp.
.
If defective,
replace
lamp (page
4-284).
Step
2.
Check
for continuity
between
socket
and ground.
.
If continuity is indicated,
replace
backup light (page
4-284).
If
no continuity is indicated,
repair
ground lead (page 3-2).
Step 3.
Disconnect
red lead from backup light. Check
for +12
VDC
at red lead (for
light on right side only).
.
If no voltage is present,
repair
red lead (page
3-2).
3-50