TM 9-2320-302-20
0145 00-3
SECONDARY AIR TANK AND FITTINGS REPLACEMENT - CONTINUED
0145 00
INSTALLATION
WARNINGS
Adhesives and sealing compounds can burn easily, can give off harmful vapors, and are harmful to skin
and clothing. To avoid injury or death, keep away from open fire and use in a well-ventilated area. If
adhesives or sealing compound contacts skin or clothing, wash immediately with soap and water.
Ensure all air lines and fittings are clear of debris and excess pipe sealing compound does not enter air
lines or fittings. Failure to follow this warning could result in injury to personnel and damage to equip-
ment.
NOTE
Perform steps 1 and 2 only if fittings were removed from air tank.
1.
Coat pipe threads of drain valve (30), pressure protect valve (29), bushing (28), tee (27), connector (26), plug (25),
check valve (24), and four elbows (23) with pipe sealing compound.
2.
Install drain valve (30), pressure protect valve (29), bushing (28), tee (27), connector (26), plug (25), check valve (24)
and four elbows (23) in air tank (3).
3.
Install two brackets (22) with two washers (21), screws (20), washers (19), and new lock nuts (18).
4.
Install two mounting brackets (17), clamps (16), washers (15), and new lock nuts (14).
5.
Install two brackets (13), washers (12), and new lock nuts (11).
6.
Install cable (10), two washers (9), screws (8), washers (7), and new lock nuts (6).
7.
Install air tank (3) with two screws (5), and new lock nuts (4).
8.
Connect hose (2) and four tubes (1) to air tank (3).
9.
Perform air system PMCS leak test (WP 0021 00).
END OF WORK PACKAGE