TM 9-2320-302-20
0144 00-2
PRIMARY II AIR TANK AND FITTINGS REPLACEMENT
0144 00
INSTALLATION
NOTE
Perform steps 1 and 2 only if fittings or air tank were replaced.
1.
Install two mounting brackets (7) on air tank (2) with two screws (6) and new lock nuts (5).
WARNING
Adhesives and sealing compounds can burn easily, can give off harmful vapors, and are harmful to skin
and clothing. To avoid injury or death, keep away from open fire and use in a well-ventilated area. If
adhesives or sealing compound contacts skin or clothing, wash immediately with soap and water.
Ensure all air lines and fittings are clear of debris and excess pipe sealing compound does not enter air
lines or fittings. Failure to follow this warning could result in injury to personnel or damage to equip-
ment.
2.
Lightly coat threads of drain valve (10), plug (9), and three elbows (8) with pipe sealing compound. Install drain valve,
plug, and three elbows on air tank (2).
3.
Install air tank (2) with four washers (4) and new lock nuts (3).
4.
Connect three tubes (1) to air tank (2).
5.
Perform air system PMCS leak test (WP 0021 00).
6.
Install spare tire (TM 9-2320-302-10).
END OF WORK PACKAGE
7
7
5,6
4
4
3
3
9
2
8
1
8
8
10
1