TM 9-2320-302-20
0058 00-1
BATTERY EQUALIZER REPLACEMENT
0058 00
THIS WORK PACKAGE COVERS
Removal, Installation
INITIAL SETUP
Tools and Special Tools
Tool kit, general mechanics (Item 36, WP 0236 00)
Materials/Parts
Tags, marker (Item 31, WP 0235 00)
Personnel Required
Two
References
TM 9-2320-302-10
Equipment Condition
Battery cables disconnected (WP 0115 00)
REMOVAL
NOTE
Tag wires to aid in installation.
1.
Remove nut (1), two washers (2), bolt (3), and cable lead (4) from GND terminal (5).
2.
Remove nut (6), two washers (7), bolt (8), and two cable leads (9) from 12V terminal (10).
3.
Remove nut (11), two washers (12), bolt (13), and two cable leads (14) from 24V terminal (15).
3
2
4
5
1
2
6
7
10
15
8
7
9
13
12
14
12
11