TM 5-2330-325-14&P
4-57.
DUMP VALVE REPLACEMENT (Continued).
b.
Cleaning.
WARNING
Solvents can burn easily, can give off harmful vapors, and are harmful to skin
and clothing. To avoid injury or death, keep away from open fire and use in a
well-ventilated area. If solvent gets on skin or clothing, wash immediately with
soap and water.
(1)
Remove grease and oil with cleaning compound and a clean soft rag.
c.
Valve Inspection.
(1)
Inspect for damage or excessive wear.
(2)
Replace defective drain valve.
d.
Installation.
(1)
Apply anti-seize tape to threads of dump valve (1) and install valve onto air reservoir (2)
(2)
Connect dump valve release cable (3) to dump valve (1).
FOLLOW-ON TASKS:
None.
4-78