FINAL COMPONENT ASSEMBLY - CONTINUED
FINAL COMPONENT ASSEMBLY - CONTINUED

Repair Parts For Air Conditioner And Stowage Box Kit Model 7336 And Het Model 1070, 8X8 Page Navigation
  44    45    46    47    48  49  50    51    52    53    54  
img
.
TB 9-2320-360-13&P-1
A/C KIT INSTALLATION - CONTINUED
0003 00
FINAL COMPONENT ASSEMBLY - CONTINUED
0003 00
WARN I N G
Always wear gloves and goggles when drilling and grinding. Failure to follow this warning may cause
injury to personnel.
N OT E
The following step does not apply to armored vehicles.
Cut firewall insulation to allow enough clearance for a 5/16-inch diameter mounting hole.
(3)
Install twist bracket (6) on firewall (5) at upper corner of tunnel (7).
(a) Drill a 5/16-inch diameter hole in
firewall (5).
(b) Install twist bracket (6) on firewall
(5) with screw (8) and nut (9), pro-
vided with the kit.
HETF00413
b.
For all vehicles: Install A/C hoses, shutoff valves, and cushion clamps.
N OT E
Refer to WP 0057 00 for A/C Refrigerant Schematic.
(1)
Install #6 O-ring (10) in hose connector (11) of #6 A/C hose (12) from A/C evaporator.
(2)
Install #6 male shutoff valve (13) on #6 A/C hose (12) from A/C evaporator.
(3)
Install #6 O-ring (14) in hose connector (15) of #6 A/C hose (16) to receiver/dryer.
(4)
Install #6 female shutoff valve (17) on #6 A/C hose (16) to receiver/dryer.
(5)
Connect #6 shutoff valves (13 and 17).
HETF00414
0003 00-43