TB 9-2320-279-13&P-4
0024
HEAVY-DUTY WINCH
HIGH-IDLE ON/OFF SWITCH
SWITCH
TERMINALS
HEAVY-DUTY
WINCH CONTROL
STATION
HEAVY-DUTY WINCH
HIGH-IDLE ON/OFF SWITCH
Figure 17.
4. Connect negative (-) probe of multimeter to heavy-duty winch control station HIGH IDLE ON/OFF switch terminal
opposite side.
5. Multimeter should display a reading less than 200 ohms. Note reading.
CONDITION/INDICATION
Is continuity measured across heavy-duty winch control station HIGH IDLE ON/OFF switch when switch is in
the ON position?
DECISION
No - Replace HIGH IDLE ON/OFF switch. (WP 0063)Test 42 - Does high idle operate?
Yes - Test 18 - Is continuity measured on heavy-duty winch valve control harness wire 1843?