TB 9-2320-279-13&P-4
0024
DECISION
No - Test 9 - Are 22 to 28 vdc measured on wire 1854 at heavy-duty winch control station remote control
connector, terminal C?
Yes - Test 3 - Are 22 to 28 vdc measured on wire 1854 at heavy-duty winch control station remote control
connector, terminal C?
TEST 3 - Are 22 to 28 vdc measured on wire 1854 at heavy-duty winch control station remote control
connector, terminal C?
WARNING
Remove all jewelry such as rings, ID tags, bracelets, etc. prior to working on or around
vehicle. Jewelry and tools can catch on equipment, contact positive electrical circuits, and
cause a direct short, severe burns, or electrical shock. Failure to comply may result in injury
or death to personnel.
1. Connect positive (+) probe of multimeter to wire 1854 at heavy-duty winch control station remote control
connector, terminal C. Refer to schematics.
HEAVY-DUTY
WINCH CONTROL
STATION
HEAVY-DUTY
WINCH CONTROL
VALVE HARNESS
REMOTE CONTROL
CONNECTOR
E
A
D
B
C
Figure 3.
2.
Connect negative (-) probe of multimeter to known good ground.
3.
Multimeter should display a reading between 22 and 28 vdc. Note reading.
4.
Set PTO ENGAGE switch to OFF position. (WP 0015)
5.
Shut OFF engine (refer to TM 9-2320-279-10).
CONDITION/INDICATION
Are 22 to 28 vdc measured on wire 1854 at heavy-duty winch control station remote control connector, terminal
C?