TM 9-2320-363-34-2
A I R C O N D I T I O N E R E X P A N S I O N V A L V E R E P L A C E M E N T
This task covers:
a. Removal b. Installation
Applicable Configuration:
All except M915A2 and M916A1
Tools and Special Equipment:
Tool Kit, SC 5180-90-CL-N26
Shop Equipment, SC 4910-95-CL-A31
Gage, Oil Level, 99-431
Recovery and Recycling System, 34400
Leak Detector, 16500
Equipment Condition:
Reference
Condition Description
Page 11.1-2
Refrigerant Recovered
General Safety Instructions:
WARNING
Use care to prevent refrigerant from
touching your skin or eyes, because
liquid refrigerant, when exposed to air,
quickly evaporates and will freeze skin or
eye tissue. Serious injury or blindness
could result if you come in contact with
liquid refrigerant.
Materials/Parts:
Packing, Preformed
Packing, Preformed
Receiver-Drier
Cap and Plug Set
Caulk, Strip
Loctite
Oil, Refrigerant
Refrigerant, R-134a
Tags, Identification
Tape, Insulation
References:
P/N 2-011C944-70
P/N 2-015C944-70
P/N 088335-00
Appendix B, Item 7.1
Appendix B, Item 7.2
Appendix B, Item 33
Appendix B, Item 43.1
Appendix B, Item 48.1
Appendix B, Item 55
Appendix B, Item 57.1
TM 9-2320-363-10
TM 9-2320-363-20
Refrigerant
R-134a air conditioning
systems should not be pressure tested or
leak tested with compressed air
Combustible mixtures of air and R-134a
may form, resulting in a fire or explosion.
which could cause personal injury.
1.
REMOVE NINE SCREWS (1) AND DASH
PANEL (2).
2.
REMOVE THE INSULATING TAPE AND
S T R I P C A U L K F R O M A R O U N D
EXPANSION VALVE.
25-52