TM 9-2320-363-34-2
TURBOCHARGER REPAIR (CONT)
7.
8.
INSTALL NEW SEAL RING (11) IN GROOVE IN CENTER HOUSING (2).
INSTALL BACKPLATE (12) AND SECURE WITH FOUR NEW BOLTS (13). TIGHTEN BOLTS TO
90-105 LB-IN. (10.1 -11.4 N.m).
W A R N I N G
Adhesives, solvents, and sealing compounds can burn easily, can give off
harmful vapors, and are harmful to skin and clothing. To avoid injury or
death, keep away from open fire and use in well-ventilated area. If adhesive,
solvent, or sealing compound gets on skin or clothing, wash immediately with
soap and water.
9.
COAT THREADS OF OIL INLET CONNECTOR (14) WITH PIPE SEALANT AND INSTALL
CONNECTOR (14) IN CENTER HOUSING (2).
10. INSTALL TURBINE WHEEL SHROUD (15) ON CENTER HOUSING (2).
12-178