TM 9-2320-363-20-1
ABS FUNCTION MENU (CONT)
Table 34. ABS Function Menu Display Definitions
Display
Definition
EXISTING FAULT
Provides description of a fault that is presently active.
NOTE
Stored faults are cleared from the ECU memory by using the fight(+)
and left (- ) arrow keys to move the brackets [ ] over "Y" to clear a
stored fault or over N to maintain a stored fault, and pressing the
ENTER key.
STORED FAULTS
Provides a description of any faults stored in memory, but are not presently
active. If more than one stored fault is stored in memory, use the up ( T ) and
down ( J ) arrow keys to display additional faults.
PROGRAM ID
Stores ABS/ATC (Anti-Lock Brake System/Automatic Traction Control) ECU
production information (e.g., software version number, part number, build
date).
COMPONENT TESTS
Accesses the
Component Tests Menu.
RS-232 SERIAL PORT
Used only when a printer is connected to Pro-Link.
CONTRAST ADJUST
Adjusts viewing angle of display.
4. Press the FUNC key to exit each function and return to the ABS Function Menu.
COMPONENT TESTS MENU
1. The Component Test Menu is accessed from the ABS Function Menu and provides the available
component tests.
2. Using the up ( ~ ) and down (-) arrow keys on the Pro-Link keypad, scroll through the listed selections
until the required testis located.
3. Press the ENTER key on the keypad to select the displayed test.
3-100.4
Change 2