TM 9-2320-363-10
Table 3-1. Troubleshooting (Con't).
MALFUNCTlON
TEST OR INSPECTION
CORRECTIVE ACTlON
Step 4.
Excessive air seal leakage during cold weather startup can
occur. If tires are not damaged, continue operation.
Continue to operate vehicle. Condition should correct itself
as seals warm-up. If condition does not correct itself, notify
Unit Maintenance.
6.
CTIS SELECTOR PANEL INDICATES FOUR MODE LIGHTS FLASHING.
Step 1.
Check condition of tires.
If tire has a slow leak or minor puncture, select RUN FLAT
on CTIS selector panel and continue operation. Change tire
as soon as tactical situation permits.
Step 2.
Check whether air reservoir draincocks are closed and posi-
tion of trailer air supply control valve.
Close air reservoir draincocks and pull valve out (OFF).
Step 3.
Check for broken or kinked air lines.
If air lines are broken or kinked, notify Unit Maintenance.
Step 4.
Excessive air seal leakage during cold weather startup can
occur. If tires are not damaged, continue operation.
Continue to operate vehicle. Condition should correct itself
as seals warm-up. If condition does not correct itself, notify
Unit Maintenance.
7.
CTIS SELECTOR PANEL INDICATES TWO MODE LIGHTS ON SOLID.
Step 1.
Press any mode key and attempt a pressure change.
If pressure change is successful, continue mission.
Step 2.
Check whether air reservoir draincocks are closed and posi-
tion of trailer air supply control valve.
Close air reservoir draincocks and pull valve out (OFF).
Step 3.
Check for broken or kinked air lines.
If air lines are broken or kinked, notify Unit Maintenance.
3-8