TM 9-2320-302-34
0119 00-2
AIR CONDITIONER CONDENSER REPLACEMENT - CONTINUED
0119 00
REMOVAL - CONTINUED
1.
Tag and disconnect refrigerant lines (1) from condenser (2). Install plugs in refrigerant and condenser lines. Remove and
discard preformed packings.
2.
Remove fasteners attaching condenser (2) to radiator.
INSTALLATION
1.
Position condenser (2) on radiator and install fasteners.
2.
Remove plugs from refrigerant lines (1) and line ports on new condenser (2).
3.
Install new preformed packings and apply refrigerant oil to preformed packings.
4.
Apply loctite to male fitting threads and connect but do not tighten refrigerant lines (1) to condenser (2).
NOTE
DO NOT connect refrigerant fittings using only one wrench. Hold one fitting in place using a wrench and
turn other fitting with a second wrench.
5.
Tighten connections in accordance with WP 0123 00.
NOTE
Any time air conditioning system refrigerant is evacuated, replace receiver-drier.
6.
Replace receiver-drier (WP 0118 00).
7.
Service air conditioner compressor (WP 0116 00).
8.
Charge air conditioning system (WP 0112 00).
1