TM 9-2320-302-34
0119 00-1
AIR CONDITIONER CONDENSER REPLACEMENT
0119 00
THIS WORK PACKAGE COVERS
Removal, Installation
INITIAL SETUP
Maintenance Level
Direct Support
Tools and Special Tools
Tool kit, general mechanics (Item 132, WP 0126 00)
Crowfoot attachment set (Item 28, WP 0126 00)
Gloves, rubber (Item 40, WP 0126 00)
Goggles (Item 42, WP 0126 00)
Wrench, torque, 0-300 lb-in (Item 137, WP 0126 00)
Wrench, torque, 15-75 lb-ft (Item 138, WP 0126 00)
Materials/Parts
Packing, preformed (P/N J200AR11)
Packing, preformed (P/N 2-013C557-70)
Adhesive, loctite (Item 2, WP 0125 00)
Cap set (Item 7, WP 0125 00)
Oil, refrigerant (Item 27, WP 0125 00)
Rags, wiping (Item 31, WP 0125 00)
Tags, marker (Item 35, WP 0125 00)
References
TM 9-2320-302-20
Equipment Condition
Refrigerant recovered (WP 0112 00)
WARNING
Use care to prevent refrigerant from touching your skin or eyes. Liquid refrigerant, when exposed to air,
quickly evaporates and will freeze skin or eye tissue. Serious injury or blindness may result if you come
in contact with liquid refrigerant.
Refrigerant R-134a air conditioning systems should not be pressure tested or leak tested with com-
pressed air. Combustible mixtures of air and R-134a may form, resulting in a fire or explosion, which
could cause personnel injury or death.
REMOVAL
CAUTION
Water and dirt can damage refrigerant system. Five minutes of not being capped is the limit for any hose or
component. DO NOT blow shop air through refrigerant hoses. Shop air is wet (humid).
NOTE
DO NOT disconnect refrigerant fittings using only one wrench. Hold one fitting in place using a wrench and
turn other fitting with a second wrench.