TM 9-2320-302-34
0118 00-2
AIR CONDITIONER RECEIVER-DRIER REPLACEMENT - CONTINUED
0118 00
REMOVAL - CONTINUED
1.
Tag and disconnect refrigerant lines (1) from receiver-drier (2). Install plugs in refrigerant lines. Remove and discard
preformed packings.
2.
Loosen hose clamp (3) attaching receiver-drier (2) to mounting bracket and remove receiver-drier.
INSTALLATION
1.
Position receiver-drier (2) in mounting bracket. Tighten hose clamp (3).
2.
Remove plugs from refrigerant lines (1) and line ports on new receiver-drier (2).
3.
Install new preformed packings and apply refrigerant oil to preformed packings.
4.
Apply loctite to male fitting threads and connect refrigerant lines (1) to receiver-drier (2). Apply proper torque in accor-
dance with WP 0123 00.
5.
Service air conditioner compressor (WP 0116 00).
6.
Install fan cycling switch (WP 0120 00).
7.
Install binary switch (TM 9-2320-302-20).
8.
Charge air conditioning system (WP 0112 00).
WARNING
Refrigerant R-134a air conditioning systems should not be pressure tested or leak tested with compressed
air. Combustible mixtures of air and R-134a may form, resulting in a fire or explosion, which could cause
personnel injury or death.
9.
Leak test air conditioning system (TM 9-2320-302-20).
END OF WORK PACKAGE
1
3