TM 9-2320-302-34
0045 00-5
GARRETT TURBOCHARGER WASTEGATE ACTUATOR MAINTENANCE - CONTINUED
0045 00
ADJUSTMENT - CONTINUED
NOTE
If travel is within limits, relieve and disconnect air pressure to wastegate actuator. If travel is not within lim-
its, proceed to next step to adjust actuator rod travel.
10.
Loosen jamnut (14) on actuator rod (9).
11.
Remove retaining clip (8) securing actuator rod (9) to wastegate lever pin (11).
12.
Remove actuator rod (9) from wastegate lever pin (11). Turn rod 1/2 turn [180 degrees = 0.020 in (0.5 mm)] clockwise
to increase, or counterclockwise to decrease setting.
13.
Repeat steps 7 and 8 to check if adjustment of travel rod is within limits.
14.
Install retaining clip (8) on wastegate lever pin (11) and tighten jamnut (14) while holding actuator rod (9).
15.
Disconnect hose (2) from regulated air source and reconnect hose to wastegate (3).
END OF WORK PACKAGE
11
8
9
3
2
14