TM 9-2320-302-34
0044 00-5
3K TURBOCHARGER WASTEGATE ACTUATOR MAINTENANCE - CONTINUED
0044 00
ADJUSTMENT - CONTINUED
12.
Remove actuator rod (5) from wastegate lever (7). Turn rod 1/2 turn [180 degrees = 0.020 in (0.5 mm)] clockwise to
increase, or counterclockwise to decrease setting.
13.
Repeat steps 7 and 8 to check if adjustment of travel rod is within limits.
14.
Install retaining ring (4) on wastegate lever (7) and tighten jamnut (17) on actuator rod (5).
15.
Disconnect regulated air supply from actuator (3). Connect hose (2) to wastegate (3).
END OF WORK PACKAGE