TM 9-2320-302-34
0045 00-3
GARRETT TURBOCHARGER WASTEGATE ACTUATOR MAINTENANCE - CONTINUED
0045 00
INSTALLATION
1.
Coat three bolts (12) with high temperature antiseize compound.
2.
Position wastegate (3) on turbocharger (13) and hand tighten three bolts (12).
3.
Loosen jamnut (14) on actuator rod (9).
4.
While holding turbocharger lever (11) down (closed), turn end of actuator rod (9) until hole in rod aligns with stud (10)
on turbocharger lever.
5.
Secure actuator rod (9) end to stud (10) on turbocharger lever (11) with new retaining clip (8).
6.
Turn actuator rod (9) end five revolutions in direction of wastegate (3) and tighten jamnut (14).
7.
Tighten three bolts (12) to 180 lb-in (20 Nm).
8.
Install elbow (7).
9.
Install hose (2) and hose clip (6) to elbow (7).
10.
Install hose (2) and hose clip (1) to wastegate (3).
11.
Install hose (2), hose clamp (5), and bolt (4).
1
2
5
4
3