0035 00-4
AUTOMATIC ETHER STARTING AID MAINTENANCE - CONTINUED
0035 00
AUTOMATIC STARTING AID INSTALLATION - CONTINUED
8.
Connect ether tube (9) to atomizer (11).
9.
Connect ether tube (9) to fitting (10).
10.
Connect ether control relay harness connector (6) to main harness connector (5).
11.
Connect harness connector (8) to main harness connector (7).
12.
Turn on ignition (TM 9-2320-302-10).
13.
Red indicator light (26) on ether control relay (15) should be ON.
14.
Run a magnet over plate (27) on ether control relay (15). Red indicator light (26) should go OFF.
FUEL CYLINDER INSTALLATION
NOTE
Replacement fuel cylinder comes with a new gasket.
1.
Apply thin coat of lubricating oil to new gasket (4) and threads of new fuel cylinder (2).
2.
Install gasket (4) and fuel cylinder (2) to valve (3). Tighten clamp (1).
3.
Turn on ignition (TM 9-2320-302-10).
4.
Red indicator light (26) on ether control relay (15) should be ON.
5.
Run a magnet over plate (27) on ether control relay (15). Red indicator light (26) should go OFF.
END OF WORK PACKAGE