(8)
Rotate the six-sided allen stud (9) clockwise to raise the pressure setting on the directional
control valve (10). Set the pressure as high as possible but do not exceed 3000 psi. The
pressure gauge (1) on the directional control valve can now be used to verify the pressure
setting of the prime mover supply system.
FOLLOW-ON TASKS:
None.