TM 5-2330-325-14&P
4-40.
12-VOLT RECEPTACLE REPLACEMENT (Continued).
b.
Installation.
(1)
Position receptacle (6) on gooseneck (2) and secure with two screws (8), washers (7), and
new self-locking nuts (1).
(2)
Connect wires (4) to connector (5) per wire tags.
(3)
Insert connector (5) in receptacle (6) and turn counter clockwise to set.
(4)
Slide boot (3) over connector (5).
2
1
3
4
5
6
7
8
FOLLOW-ON TASKS:
Check electrical system for proper operation.
4-39