REMOVAL
1.
Disconnect connector (Figure 1, Item 6).
2.
Remove four self-locking nuts (Figure 1, Item 3), washers (Figure 1, Item 2), and screws (Figure 1, Item 1),
disconnect ground wire (Figure 1, Item 5), and remove receptacle converter box (Figure 1, Item 4). Discard
self-locking nuts (Figure 1, Item 3).
1
2
6
3
4
466-0071
5
Figure 1.
Receptacle Converter Box Replacement.
END OF TASK
INSTALLATION
1.
Install receptacle converter box (Figure 1, Item 4) and connect ground wire (Figure 1, Item 5) with four
screws (Figure 1, Item 1), washers (Figure 1, Item 2), and new self-locking nuts (Figure 1, Item 3).
2.
Connect connector (Figure 1, Item 6).
END OF TASK
FOLLOW ON TASK
Connect power source and test electrical system for proper operation.