TM 5-2330-325-13&P
OPERATOR MAINTENANCE
BRAKES WILL NOT RELEASE
INITIAL SETUP:
References
TROUBLESHOOTING PROCEDURE
SYMPTOM
BRAKES WILL NOT RELEASE
MALFUNCTION
AIR SUPPLY NOT FLOWING
CORRECTIVE ACTION
Release towing vehicle parking brake to start air flow to semitrailer.
MALFUNCTION
LOW AIR PRESSURE
CORRECTIVE ACTION
Build air pressure up to required level.
MALFUNCTION
PACKING IS LEAKING
CORRECTIVE ACTION
Check air line connection at gladhands.
a.
b.
If packing is leaking, notify Field Maintenance.
0011-1
02/13/2013root(tswp)wpno(T1005)