TB 9-2320-360-13&P-1
THIS WORK PACKAGE COVERS
Removal, Installation
INITIAL SETUP
Materials/Parts - Continued
Maintenance Level
#6 O-Ring (Item 27, Figure 1, WP 0062 00)
Direct Support
#8 O-Ring (Item 37, Figure 1, WP 0062 00)
Tools and Special Tools
Tool Kit, General Mechanic (Item 10, WP 0060 00)
References
Materials/Parts
Sealant, Loctite (Item 8, WP 0061 00)
Equipment Conditions
Wheels chocked (TM 9-2320-360-10)
Tags, Identification (Item 14, WP 0061 00)
Hood opened (TM 9-2320-360-10)
Locknut (8) (Item 15, Figure 1, WP 0062 00)
Locknut (4) (Item 16, Figure 1, WP 0062 00)
REMOVAL
WAR N I N G
Use care to prevent refrigerant from touching your skin or eyes. Be sure to wear proper protective goggles and non-
leather golves when servicing Air Conditioning systems to prevent injury. Liquid refrigerant, when exposed to air,
quickly evaporates and will freeze skin or eye tissues. Serious injury or blindness may result if you come in
contact with liquid refrigerant.
CAU T I ON
Cap and plug all lines and fittings or damage to equipment may result.
N OT E
Tag and mark all wires prior to removal.
Tag and mark lines prior to removal.
1.
Remove shutoff valve straight adapter (1) and #8 O-ring (2) from A/C condenser coil assembly (3). Discard O-ring.
HETF00565