A/C DOES NOT OPERATE - Continued
A/C DOES NOT OPERATE - Continued

Repair Parts For Air Conditioner And Stowage Box Kit Model 7336 And Het Model 1070, 8X8 Page Navigation
  240    241    242    243    244  245  246    247    248    249    250  
img
. . . . . .
TB 9-2320-360-13&P-1
WAR N I N G
Always use caution when approaching a hot engine. Failure to do so may result in serious burns.
Wear protective goggles and nonleather gloves when servicing A/C or injury may result.
VISUAL INSPECTION
(1) Turn engine switch to OFF position
(TM 9-2320-360-10).
(2) Remove two screws and doghouse
door (WP 0028 00).
(3) Inspect A/C expansion valve. Note if
A/C expansion valve is free from
excessive sweating and frost.
(4) Recover R-134a (WP 0056 00).
(5) If A/C expansion valve was not free
from excessive sweating and frost in
Step 3 above, replace A/C expansion
valve (WP 0049 00). Verify repair, go to
Step 23 of this fault.
(6) If A/C expansion valve was free from
excessive sweating and frost in Step 3
above, replace A/C evaporator
(WP 0050 00). Verify repair, go to Step
23 of this fault.
(7) Replace A/C receiver/dryer
(WP 0054 00).
(8) Evacuate and charge system
(WP 0056 00).
(9) Verify repair, go to Step 23 of this fault.
HETF00485
0042 00-27