A/C DOES NOT OPERATE - Continued
A/C DOES NOT OPERATE - Continued

Repair Parts For Air Conditioner And Stowage Box Kit Model 7336 And Het Model 1070, 8X8 Page Navigation
  235    236    237    238    239  240  241    242    243    244    245  
img
. . .
TB 9-2320-360-13&P-1
A/C DOES NOT OPERATE
16.
WARNING
KNOWN INFO
Read WARNING on
Power to A/C system OK.
page 0042 00-23.
A/C circuit wiring OK.
A/C controls OK (except for A/C
Does A/C test set recovery/
binary switch and A/C
recycling manifold gages
thermostatic switch).
indicate high system high
A/C receiver/dryer moisture
TEST OPTIONS
side pressure?
indicator indicates no moisture in
Pressure Test.
system.
A/C Test Set Manifold Gage.
A/C binary switch OK.
A/C receiver/dryer sight glass
REASON FOR QUESTION
indicates no desiccant
To isolate system fault.
breakdown or oil in system.
A/C system is not leaking.
A/C system charge is not low.
A/C thermostatic switch OK.
Go to Step 19 of
No air or other contaminant in A/C
NO
this fault.
system.
A/C compressor OK.
YES
A/C engine fan control circuit OK.
A/C condenser OK.
A/C system is not overcharged.
POSSIBLE PROBLEMS
Restricted A/C hose.
A/C expansion valve faulty.
A/C receiver/dryer faulty.
A/C evaporator faulty.
KNOWN INFO
TEST OPTIONS
17.
WARNING
Read WARNING on
Power to A/C system OK.
Visual Inspection.
page 0042 00-23.
A/C circuit wiring OK.
REASON FOR QUESTION
A/C controls OK (except for A/C
If frost or cool spots are forming on
Are A/C hoses from A/C
binary switch and A/C
A/C hoses, A/C hoses are
compressor output to A/C
thermostatic switch).
restricting R-134a flow.
A/C receiver/dryer moisture
expansion valve free from
indicator indicates no moisture in
frost and cool spots?
system.
A/C binary switch OK.
A/C receiver/dryer sight glass
indicates no desiccant
breakdown or oil in system.
A/C system is not leaking.
A/C system charge is not low.
Replace restricted A/C
A/C thermostatic switch OK.
hose (WP 0052 00), A/C
No air or other contaminant in A/C
receiver/dryer (WP 0054
NO
system.
00), and R-134a (WP 0056
A/C compressor OK.
00). Verify repair, go to
A/C engine fan control circuit OK.
YES
Step 23 of this fault.
A/C condenser OK.
A/C system is not overcharged.
A/C evaporator OK.
POSSIBLE PROBLEMS
Restricted A/C hose.
A/C expansion valve faulty.
A/C receiver/dryer faulty.
0042 00-22