• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
A/C DOES NOT OPERATE - Continued
A/C DOES NOT OPERATE - Continued

Repair Parts For Air Conditioner And Stowage Box Kit Model 7336 And Het Model 1070, 8X8 Page Navigation
  241    242    243    244    245  246  247    248    249    250    251  
img
. . . . . . .
TB 9-2320-360-13&P-1
A/C DOES NOT OPERATE
KNOWN INFO
21.
WARNING
Read WARNING on
Power to A/C system OK.
page 0042 00-29.
A/C circuit wiring OK.
A/C controls OK (except for A/C
Is continuity measured
binary switch and A/C
across A/C binary switch
thermostatic switch).
terminals?
A/C receiver/dryer moisture
TEST OPTIONS
indicator indicates no moisture in
Continuity Test.
system.
Multimeter.
A/C receiver/dryer sight glass
indicates no desiccant
REASON FOR QUESTION
breakdown or oil in system.
If continuity is measured, A/C
Restricted A/C hose.
compressor is faulty.
A/C thermostatic switch OK.
No air or other contaminant in A/C
system.
Go to Step 22 of
A/C engine fan control circuit OK.
this fault.
NO
A/C condenser OK.
A/C expansion valve OK.
A/C system is not overcharged.
YES
A/C receiver/dryer OK.
A/C evaporator OK.
Replace A/C compressor
POSSIBLE PROBLEMS
(WP 0045 00), A/C
A/C compressor faulty.
receiver/dryer (WP 0054
A/C system charge low.
00), and R-134a (WP 0056
A/C system leaking.
00). Verify repair, go to
A/C binary switch faulty.
Step 23 of this fault.
22.
KNOWN INFO
TEST OPTIONS
WARNING
Read WARNING on
Power to A/C system OK.
Pressure Test.
page 0042 00-29.
A/C circuit wiring OK.
A/C Test Set Manifold Gage.
A/C controls OK (except for A/C
REASON FOR QUESTION
Does A/C test set recovery/
binary switch and A/C
If 34 psi pressure is measured, A/C
recycling manifold system
thermostatic switch).
binary switch is faulty. If not,
low side gage indicate a
A/C receiver/dryer moisture
system charge is low.
indicator indicates no moisture in
pressure of at least 34 psi?
system.
A/C receiver/dryer sight glass
indicates no desiccant
breakdown or oil in system.
Restricted A/C hose.
A/C thermostatic switch OK.
Check system for
No air or other contaminant in A/C
damage and loose
system.
fittings, perform leak test
A/C engine fan control circuit OK.
(WP 0038 00), repair
NO
A/C engine fan control circuit OK.
damage and leaks
A/C condenser OK.
found, replace receiver/
A/C expansion valve OK.
YES
dryer (WP 0054 00), and
A/C system is not overcharged.
replace R-134a
A/C receiver/dryer OK.
(WP 0056 00).
A/C evaporator OK.
A/C compressor OK.
Replace A/C
POSSIBLE PROBLEMS
binary switch
A/C system charge low.
(WP 0044 00).
A/C system leaking.
Verify repair, go to
A/C binary switch faulty.
step 23 of this
repair.
0042 00-28