TB 9-2320-360-13&P-1
0036 00
INSTALLATION - CONTINUED
14.
Install cushion clamp (11) on hoses (18 and 19) with screw (9) and washer (10).
15.
Lightly coat new #6 O-ring (12) and new #12 O-ring (13) with refrigerant compressor oil.
16.
Install shutoff valve (3) and #6 O-ring (12) on shutoff valve (4).
17.
Install shutoff valve (7) and #12 O-ring (13) on shutoff valve (8).
18.
Install cushion clamp (16) on hoses (18 and 19) with screw (14) and washer (15).
19.
Open shutoff valves (3 and 4) and install two caps (1 and 2).
20.
Open shutoff valves (7 and 8) and install two caps (5 and 6).
HETF00429
21.
Perform leak test inspection (WP 0038 00).
22.
Connect batteries (TM 9-2320-360-20-2).
23.
Close hood (TM 9-2320-360-10).
24.
25.
Remove wheel chocks (TM 9-2320-360-10).
END OF WORK PACKAGE
0036 00-7/(0036 00-8 Blank)