A/C EVAPORATOR SUBSYSTEM REPLACEMENT - CONTINUED
A/C EVAPORATOR SUBSYSTEM REPLACEMENT - CONTINUED

Repair Parts For Air Conditioner And Stowage Box Kit Model 7336 And Het Model 1070, 8X8 Page Navigation
  196    197    198    199    200  201  202    203    204    205    206  
img
TB 9-2320-360-13&P-1
A/C EVAPORATOR SUBSYSTEM REPLACEMENT - CONTINUED
0036 00
REMOVAL - CONTINUED
CAU T I ON
Keep all non-connected ports on valves clean and capped during removal, or damage to equipment may
result.
8.
Loosen two clamps (21) from A/C louver ducts (22) and place to side of doghouse compartment (23).
9.
Disconnect two plugs (24) from A/C evaporator wiring harness (25).
10.
Disconnect four drain tubes (26) from A/C evaporator (27).
11.
Remove 10 screws (28), washers (29) and two mounting brackets (30) from A/C evaporator (27) and doghouse compart-
ment (23).
CAU T I ON
When removing the evaporator, pull the hoses through the grommet at intervals. Use the alternator access
opening during the removal process to prevent the hoses from becoming lodged in doghouse and damaging
evaporator connections.
12.
With the aid of an assistant, remove two hoses (18 and 19) backwards through right-side alternator access hole.
HETF00426