TB 9-2320-302-13&P-3
EVAPORATOR ASSEMBLY MAINTENANCE - CONTINUED
0017 00
INSTALLATION - CONTINUED
NOTE
Install hoses and wires as tagged during removal.
8.
Connect RFI filter wiring harness connector (23) (yellow wire), connector (19) (black wire), and connector (18) (red
wire) to evaporator wiring harness (17).
9.
Install sprial wrap (24) and new tiedown strap (20) on evaporator wiring harness (17) as required.
WARNING
Contact with refrigerant can cause frostbite. Keep hands and face away to prevent personal injury.
Protective face shield must always be worn when refrigerant lines are opened, even if the gauges indi-
cate the system is empty.
Always use caution if a fitting is removed. Slowly loosen the fitting. If the system is still under any
pressure, release it slowly in a well-ventilated area.
DO NOT smoke when servicing A/C or wherever refrigerant gas may be present.
Failure to follow these warnings may result in injury or death to personnel.
10.
Apply refrigerant oil to new O-ring, remove cap, and install A/C hose connection (22) on evaporator assembly (1).
11.
Apply refrigerant oil to new O-ring, remove cap, and install A/C hose connection (21) on evaporator assembly (1).
17
18
19
20
21
22
1
449-051
24
23
0017 00-18