EVAPORATOR ASSEMBLY MAINTENANCE - CONTINUED
EVAPORATOR ASSEMBLY MAINTENANCE - CONTINUED

Crew Protection Kit For M915A3P1, M915A2P1, M916A3P1, M917A2P1, M915A401, M917A1P1, M916A1P1, And M916A2P1 - 3 Page Navigation
  87    88    89    90    91  92  93    94    95    96    97  
img
TB 9-2320-302-13&P-3
EVAPORATOR ASSEMBLY MAINTENANCE - CONTINUED
0017 00
ASSEMBLY - CONTINUED
NOTE
Tag wires and hoses to aid in installation.
6.
Install blower motor assembly (4), black wire ground connector (3), red wire power connector (2), and four nuts (6) on
evaporator assembly (1).
7.
Install expansion valve (7) and two fittings (8) on evaporator assembly (1).
8.
Install evaporator core assembly (10) and four screws (9) on evaporator assembly (1).
9.
Push thermostat probe (5) into evaporator core (10) fins as shown.
5
4
2
3
6
1
6
7
449-072
10
9
9
8
0017 00-14