EVAPORATOR ASSEMBLY MAINTENANCE - CONTINUED
CONDENSER REPLACEMENT

Crew Protection Kit For M915A3P1, M915A2P1, M916A3P1, M917A2P1, M915A401, M917A1P1, M916A1P1, And M916A2P1 - 3 Page Navigation
  93    94    95    96    97  98  99    100    101    102    103  
img
. . .
TB 9-2320-302-13&P-3
EVAPORATOR ASSEMBLY MAINTENANCE - CONTINUED
0017 00
INSTALLATION - CONTINUED
NOTE
Install hoses and wires as tagged during removal.
14.
Install elbow connector (2) and clip (12) on evaporator assembly (1).
15.
Install drain hose (10) and clip (11) on elbow connector (2).
16.
Install T-connector (7) and clip (3) on drain hose (10).
17.
Install drain hose (8) and clip (9) on T-connector (7).
18.
Install drain hose (5) and clip (4) on evaporator assembly (1).
19.
Install drain hose (5) and clip (6) on T-connector (7).
1
2
3
12
11
4
10
5
9
8
6
449-067
7
20.
Install air filter (WP 0010 00).
21.
Evacuate and recharge A/C system (WP 0015 00).
22.
Verify correct operation of A/C system (WP 0004 00).
END OF WORK PACKAGE