• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
COMPRESSOR REPLACEMENT - CONTINUED
COMPRESSOR REPLACEMENT - CONTINUED

Crew Protection Kit For M915A3P1, M915A2P1, M916A3P1, M917A2P1, M915A401, M917A1P1, M916A1P1, And M916A2P1 - 3 Page Navigation
  72    73    74    75    76  77  78    79    80    81    82  
img
TB 9-2320-302-13&P-3
COMPRESSOR REPLACEMENT - CONTINUED
0016 00
INSTALLATION - CONTINUED
WARNING
Contact with refrigerant can cause frostbite. Keep hands and face away to prevent personal injury.
Protective face shield must always be worn when refrigerant lines are opened, even if the gauges indi-
cate the system is empty.
Always use caution if a fitting is removed. Slowly loosen the fitting. If the system is still under any
pressure, release it slowly in a well-ventilated area.
DO NOT smoke when servicing A/C or wherever refrigerant gas may be present.
Failure to follow these warnings may result in injury or death to personnel.
NOTE
Install wires and hoses as tagged during removal.
10.
Apply refrigerant oil to new O-ring, remove cap, and install A/C hose (9) on compressor (1).
11.
Apply refrigerant oil to new O-ring, remove cap, and install A/C hose (8) on compressor (1).
8
1
9
449-057
0016 00-7