TB 9-2320-302-13&P-3
COMPRESSOR REPLACEMENT - CONTINUED
0016 00
REMOVAL
WARNING
Contact with refrigerant can cause frostbite. Keep hands and face away to prevent personal injury.
Protective face shield must always be worn when refrigerant lines are opened, even if the gauges indi-
cate the system is empty.
Always use caution if a fitting is removed. Slowly loosen the fitting. If the system is still under any
pressure, release it slowly in a well-ventilated area.
DO NOT smoke when servicing A/C or wherever refrigerant gas may be present.
Failure to follow these warnings may result in injury or death to personnel.
CAUTION
Cap all A/C hose ends and component connections during removal to protect against contamination. Failure
to comply may cause damage to equipment.
NOTE
Tag wires and hoses to aid in installation.
1.
Remove nut (3), diode harness ground connector (2), and bolt (4) from compressor (1).
2.
Disconnect compressor connector (5), chassis connector (6), and remove diode harness (7) from compressor (1).
2
3,4
5
1
6
7
449-052
0016 00-2