TM 9-2320-363-34-2
17. INSTALL OIL SEAL (13) IN BEARING CAGE (3).
(SHOWN WITHOUT BEARINGS
AND PINION)
18. USING FEELER GAGE, CHECK GAP BETWEEN OIL SEAL (13) AND BEARING CAGE (3) AT
SEVERAL POINTS AROUND OIL SEAL (13). GAP MUST BE WITHIN 0.015-0.030 IN. (0.38-0.76 mm).
DIFFERENCE BETWEEN LARGEST AND SMALLEST GAP MUST NOT EXCEED 0.01 IN. (0.25 mm).
17-61