13.
14.
15.
16.
17.
18.
NOTE
If injector tube falls off installer during installation, use injector tube reconditioning
set tube remover pilot to retain injector tube on installer. Remove pilot after
holddown clamp is installed and tightened.
INSTALL INJECTOR TUBE RECONDITIONING SET INSTALLER (14) WITH INJECTOR TUBE IN
INJECTOR BORE. MAKE SURE TIP OF INJECTOR TUBE GOES THRU SMALL HOLE IN CYLINDER
HEAD (2) FIRE DECK. TAP LIGHTLY ON END OF INSTALLER (14), IF NECESSARY, TO SEAT
INJECTOR TUBE.
INSTALL INJECTOR HOLDDOWN CLAMP (15), WASHER (16), AND BOLT (17) OVER INJECTOR
TUBE RECONDITIONING SET INSTALLER (14). TIGHTEN BOLT TO 43-49 LB-FT (58-66 N.m).
INSERT INJECTOR TUBE RECONDITIONING SET FLARING TOOL (18) THRU SMALL HOLE IN
BOTTOM OF INJECTOR TUBE (13) AND ROTATE TOOL (18) TO ENGAGE THREADS (19) IN
RECONDITIONING SET INSTALLER.
USING TORQUE WRENCH AND STANDARD 9/16-lN. SOCKET, THREAD FLARING TOOL (18) INTO
INJECTOR TUBE RECONDITIONING SET INSTALLER UNTIL IT FLARES INJECTOR TUBE (13).
ROTATE FLARING TOOL (18) AND APPLY PRESSURE TO FLARE END OF INJECTOR TUBE
FIRMLY AGAINST CYLINDER HEAD (2). DO NOT EXCEED 30 LB-FT (41 N.m).
REMOVE FLARING AND INSTALLER TOOLS. ENSURE PROPER FLARE.
12-27