TM 9-2320-363-34-2
STARTER REPAIR (CONT)
C L E A N I N G
Use general cleaning methods to clean all parts (page 2-30).
Inspect all parts for wear or damage.
1.
2.
INSTALL INSULATOR (1) IN FIELD RING (2).
INSTALL FIELD COIL (3) IN FIELD RING (2) SO THAT TERMINAL STUD HOLES IN FIELD COIL (3)
AND FIELD RING (2) LINE UP.
C A U T I O N
Pole pieces must be installed so that slot clears field coil contact tab. Failure
to do so will cause damage to starter motor.
3.
INSTALL FOUR POLE PIECES (4) AND EIGHT SCREWS (5).
C A U T I O N
Insulator must be installed between field coil and field ring. Failure to do so
will cause a short, damaging starter motor.
4.
INSTALL INSULATOR (6) AND STUD TERMINAL (7) THRU FIELD COIL (3) AND FIELD RING (2).
5.
INSTALL BUSHING (8), NEW PACKING (9), INSULATOR (10), WASHER (11), AND NUT (12) ON
STUD TERMINAL (7).
13-32