17.
REMOVE SEAL (56), BUSHING (57), AND PACKING (58) FROM SHIFT HOUSING
SEAL AND PACKING.
(39). DISCARD
18. REMOVE NUT (59), WASHER (60), INSULATOR (61), AND PACKING (62) FROM FIELD RING (13).
DISCARD PACKING.
C A U T I O N
When removing stud terminal, do not use hammer to tap stud out. To do so
could cause damage to components.
19. TO REMOVE STUD TERMINAL (63), TEMPORARILY REPLACE NUT (59) FLUSH WITH END OF
STUD. USING SUITABLE PLIERS, WORK STUD OUT WHILE SUPPORTING FIELD COIL (64).
20. REMOVE INSULATOR (65) AND BUSHING (66) FROM FIELD RING (13).
21. REMOVE EIGHT SCREWS (67), FOUR POLE PIECES (68), FIELD COIL (64), AND INSULATOR (69)
FROM FIELD RING (13).
13-31